Puna Geothermal Venture (PGV) agrees with the Element I Report conclusion that the geothermal resource encountered in the KS-8 well, although quite hot, is manageable through the use of modem well drilling and production technology. However, PGV does not agree that the KS-8 well uncontrolled flow event occurred because of inadequacies in PGV's drilling plan and procedures. PGV believes that it occurred because the drilling encountered a high temperature and high pressure geothermal resource at a depth that was more shallow than anticipated. PGV's previous experiences with the KS-7 well caused PGV to make significant changes to the drilling program implemented for KS-8, and the KS-8 well drilling program was prepared to handle any resource of similar characteristics (see PGV Response G).
However, the temperatures and pressures of the geothermal resource encountered by the KS-8 well were substantially higher than those encountered in the KS-7 well. |
|