dc.identifier.citation Puna Geothermal Venture. 1991. Report on uncontrolled flow event as per conditions #13 and #26, ATC no. A-833-795, attachment II, Wellfield. Pahoa (HI): Puna Geothermal Venture. en_US
dc.identifier.uri http://hdl.handle.net/10524/23409 en_US
dc.description Includes a cover letter. en_US
dc.description.abstract This report covers the following five items: probable cause of the blowout, actions that have or will be taken, estimated time before the well is controlled, analysis of air quality impact from unabated emissions, and air quality monitoring plan. en_US