Please use this identifier to cite or link to this item: http://hdl.handle.net/10524/47938

First quarter quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii : November 1, 1989 - January 31, 1990

Item Summary

Title:First quarter quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii : November 1, 1989 - January 31, 1990
Authors:Measurement Technologies
Keywords:True/Mid-Pacific Geothermal Venture
True Geothermal Company Monitoring Program, Kilauea Middle East Rift Zone
Hawaii Island
meteorology
Kilauea East Rift Zone
show 4 moreKilauea
Big Island
Puna
Hawaii
show less
LC Subject Headings:Hydrogen sulfide--Environmental aspects--Hawaii--Puna
Geothermal power plants--Environmental aspects--Hawaii--Puna Region
Geothermal resources--Environmental aspects--Hawaii--Puna Region
Air quality--Hawaii
Date Issued:1990
Publisher:Measurement Technologies
Citation:Measurement Technologies. 1990. First quarter quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii : November 1, 1989 - January 31, 1990. Measurement Technologies.
Series:CN-137
Quality assurance report for True Geothermal Energy Company Monitoring Program, Kilauea Middle East Rift Zone, island of Hawaii
Abstract:"The aerometric analyzer audit results were satisfactory. The sulfur dioxide (502) and hydrogen sulfide (H2S) analyzers meet the slope and intercept criteria. Although the H2S analyzer passed the slope and intercept criteria, the analyzer exhibited a large negative differential on the lower concentration range of the analyzer.
The analyzer linerizer was adjusted and a post audit was performed. The reaudit showed satisfactory results and the low range showed a smaller negative differential.
The meteorological equipment audit results were satisfactory.
The particulate sampler audit results were satisfactory.
All operational procedures followed at the monitoring sites were consistent with EPA guidelines, and all instrument/analyzer calibrations were done in a proper manner. All documentation was found to be complete, concise, and up to date."
Pages/Duration:35 pages
URI/DOI:http://hdl.handle.net/10524/47938
Appears in Collections: Miscellaneous Private Sector Reports
The Geothermal Collection


Please email libraryada-l@lists.hawaii.edu if you need this content in ADA-compliant format.

Items in eVols are protected by copyright, with all rights reserved, unless otherwise indicated.